Explosion Proof Floodlight IP68

Angles

Details

CERTIFICATES

     

COMPONENTS

PRODUCT FEATURE ICONS
Class IClass II100.000h5 YearsDimmableTHD<20%UGR<12-40ºC 60ºC
 IP68IK10
PRODUCT FEATURES
  1. Connectable technology, ease of maintenance.
  2. Cell technology of low cooling and high thermal conductivity. The structure allows fast chip cooling, high heat conduction efficiency and high thermal dissipation performance.
  3. Led-by-pass technology: If a led is damaged, it will not affect the rest, nor will it increase its operating current.
  4. Driver with intelligent technology of constant current, output of stable current, intelligent unit with numerous options, the light can be adjusted automatically by the system of regulation time.
  5. Degree of protection of the optical block IP68 and IK10, high level of protection against water and impacts.
  6. Constant flux emission system (CLO), uniform distribution of light over time.
APPLICATIONS

Lighting of explosion risk zones: mines, hydrocarbons logistics centers, industrial, etc.

LIGHT DISTRIBUTION

General Information

Product RangeProfessional
Product FamilyIndustrial Lighting
Product ModelExplosion Proof Floodlight IP68
Series ReferenceEXEPIP68
Warranty5 years
Lifespan @ Ta=25ºCL70 ~ L85 F10 100.000 h
Lifespan @ Ta=40ºCL70 ~ L85 F10 60.000 h
Voltage (V)100-277V AC
Frecuency (Hz)50-60 Hz
Power Factor (PF)>0.98
Power Efficiency (PE %)>90%
Flicker (%)0%
Total Harmonic Distorsion (THD %)<20%
Protection ClassI, II
System Luminous Efficacy (Lm/W)100-105 lm/W ±10%
Color Render Index (CRI >Ra)80
Correlated Color Temperature (CCT ºK)1700K~6000K
Color Consistency (SDCM)< 5
Unified Glare Rating (UGR)<12
Light Distribution TypeIV, XI
Beam Angle (Degrees)Diferent options regarding lens type
Upper Light Output Ratio (ULOR %)0%
Optical Compartment Tightness (IP)IP68
Auxiliary Compartment Tightness (IP)IP67
Impact Resistance (IK)IK10
Surge ProtectionBasic 4kV, Extended 10kV
Explosion-ProofII 2G Ex eb mb IIA T4 Gb, III 2D Ex tb IIIC T(95ºC) Db
PCB TypeMC-PCB
PCB MaterialAluminium
Thermal ViasYes
Led Bypass ProtectionYes
Overheating ProtectionNTC Thermistor
BrandBridgelux
Type45mil
Model
Max. Luminous Efficacy (Lm/W)
BrandMeanwell
Series TypeHLG
Internal Or ExternalExternal
Isolated Or NotIsolated
IPIP67
Lifespan @ Tc=60ºc100.000 h
Surge Protection4 kV, 10kV
Overload And Short Circuit ProtectionYes
Thermal Foldback ControlOptional

Application Conditions

Tj Temperature (Tj ºC)<80ºC @ Ta=25ºC
Tc Temperature (Tc ºC)<60ºC @ Ta=25ºC
Storage Temperature (ºC)-40ºC +85ºC
Operating Temperature (ºC)-40ºC +60ºC
Operating Humidity (%RH)5-95ºRH
Dimming Function1-10V, PWM, DALI (optional)
Scheduled Dimming System6 levels steps, Optional
Constant Light Output (CLO)Optional
Other Sensors OptionsPhotoelectric, Movement, Other
Wired Communications CompatibilityYes
Wirless Communications CompatibilityYes
TypeFixing to surface
SystemU type bracket (R optional)
Mounting Height4-12M
Fixing To Existing PoleNo
Vertical Angle AdjustmentYes
Horizontal Angle AdjustmentYes
Replaceable Light SourceNo
Replaceable DriverYes
Replaceable LensYes
Replaceable CoverYes
Housing Opening SystemStainless steel screws
Wire Connectors SystemWaterproof threaded quick connector
Thermal Interface Material (TIM)Yes
Body MaterialAluminium
Fins MaterialAluminium
Extra Cooling SystemThe whole structure of radiation
Body MaterialAluminium alloy
FinishingAluminium
Color RALYellow, Grey, Black, Green
Cover MaterialTempered glass
Cover TypeClear
Locking SystemStainless steel screws
Light Guide Plate Material
Lens MaterialPC
Reflector MaterialAluminum
Diffuser MaterialTempered glass
Cable Material3*1.0mm rubber with cold-pressed terminal
Connectors SystemsWaterproof threaded quick connector
Waterproof ConnectorsYes

Product Parameters

ReferenceSystem PowerNº LEDSCurrent (mA)System Efficacy (Lm/W)Luminous Flux (Lm)Lumen Maintenance @ Ta=25ºCTj @ Ta=25ºCDimensionsWeight (Kg)
@ 3000K@ 4000K@ 5000K@ 6000K
EXEP40WIP6840W24500mA100 lm/W ±10%3808405242084364L70 F10 100.000h78ºC200*200*270mm4,3 kg
EXEP60WIP6860W60300mA105 lm/W ±10%5998638266286873L85 F10 100.000h59ºC300*300*175mm8,4 kg
EXEP80WIP6880W400mA100 lm/W ±10%7616810484168728L75 F10 100.000h65ºC
EXEP100WIP68100W96300mA9520101301052010910L85 F10 100.000h59ºC400*400*185mm12,3 kg
EXEP120WIP68120W350mA11424121561262413092L80 F10 100.000h62ºC
EXEP150WIP68150W144300mA105 lm/W ±10%14994159551656917183L85 F10 100.000h59ºC
EXEP185WIP68185W156350mA100 lm/W ±10%17612187411946220184L80 F10 100.000h62ºC

Product Builder

Model
Power
Nº LEDS
Color CCT
Voltage
Color RAL
Lens
Control
Color CCT
Optionals
EXEPIP68(1)40W
24
(24 LEDS)
AMB
1700K 
120
100V-120V
BK
Black
LIT4
Symmetric Distribution of 120º
NC
No Control
AMB
1700K 
EXPEC001
Photoelectric control sensor
INTEGRATED
(2)60W
60
(60 LEDS)
AMB2
2200K
240
200V-240V
GR
Grey
LIT11
Asymmetric Distribution of 60ºx30º
3 IN 1
0-10V/PWM/Resistance
AMB2
2200K
PW·10KD05KWV

External surge protection device 10kv
INTEGRATED
(2)80W
96
(96 LEDS)
WW
3000K
305
90V-305V
YE

Yellow
Timer
Time Regulation System
WW
3000K
(3)100W
144
(144 LEDS)
NW
4000K
GRE

Green
PT
Ponteciometer
NW
4000K
(3)120W
156
(156 LEDS)
PW
5000K
PW
5000K
(4)150W
CW
6000K
CW
6000K
(5)185W

EXAMPLE: EXEPIP68-40W-24-NW-240-GR- LIT4-NC-EXPEC001

  1. Only for models of 24 leds.
  2. Only for models of 60 leds.
  3. Only for models of 96 leds.
  4. Only for models of 144 leds.
  5. Only for models of 156 leds.

Product dimensions

ReferenceDimensions
EXEP40WIP68200*200*270mm
EXEP60WIP68300*300*175mm
EXEP80WIP68
EXEP100WIP68400*400*185mm
EXEP120WIP68
EXEP150WIP68
EXEP185WIP68
  • Step1. Hold up the R type frame (U type frame) into installation position.
  • Step2. Mark two screw position with a pen or other tools in the wall.
  • Step3. Drill hole.
  • Step4. Install the R type frame (U type frame), fasten the screws.
  • Step5. Connect the three wires of lamp input and the power wires.
  • Step6. Adjust screw on the fixing pieces, make the lamp with a suitable irradiation angle.

Attention

  1. Adjusting the lamp direction before locking screws.
  2. Pole screws must be locked, to prevent loss or rotation.
  3. The bare wires should be insulated to prevent short circuits.
  4. Green line must be grounded to prevent leakage accidents.
ModelPcs/CtnLong (mm)Width (mm)Height (mm)Gross Weigth (kg/ctn)
40W13602502004.5
60W-80W13703702408.5
100W-185W146046024012.5

Matters need Attention

  1. Before use, should carefully read the instructions , to avoid accidents and damage.
  2. Please wear gloves to avoid injury before installation work.
  3. Lighting installation,and wiring work must be carried out in the absence of power.
  4. Power line joints must do insulation ,waterproofing treatment.
  5. Do not look directly at the light emitting LED lighting in close distance, ensure not hurt the eyes.

Uso de cookies

Este sitio web utiliza cookies para que usted tenga la mejor experiencia de usuario. Si continúa navegando está dando su consentimiento para la aceptación de las mencionadas cookies y la aceptación de nuestra política de cookies, pinche el enlace para mayor información.plugin cookies

ACEPTAR
Aviso de cookies