Street Light IP66

Angles

Details

CERTIFICATES

  

COMPONENTS

PRODUCT FEATURE ICONS
Class IClass II100.000h5 YearsDimmableTHD<20%UGR<12-40ºC 60ºC
 IP66IK10
PRODUCT FEATURES
  1. Modularization pluggable technology, free on-site maintenance tools.
  2. Low cellular cooling technology and high thermal conductivity, the whole structure of the cooling chip, efficient heat conduction and heat dissipation performance.
  3. Low single star LED light damage does not affect the other light source current.
  4. Intelligent constant current drive technology, output stability, break through the life of power, can be automatically adjusted the light.
  5. Optical compartment IP66 and IK10 protection, the highest level of protection against water and impacts.
  6. Constant Light Output (CLO), uniform distribution of light over time.
  7. Free series, full power solutions.
APPLICATIONS

Streets and urban lighting, residential and industrial areas, parks, facades, etc.

LIGHT DISTRIBUTION

General Information

Product RangeStreet lighting
Product FamilyStreet Lighting
Product ModelStreet light IP66 PRO
Series ReferenceEXSL
Warranty5 years
Lifespan @ Ta=25ºCL70 ~ L90 F10 100.000 h
Lifespan @ Ta=40ºCL70 ~ L90 F10 60.000 h
Voltage (V)90-305V AC
Frecuency (Hz)50-60 Hz
Power Factor (PF)>0.95
Power Efficiency (PE %)>90%
Flicker (%)0%
Total Harmonic Distorsion (THD %)<20%
Protection ClassI, II
System Luminous Efficacy (Lm/W)100-110 lm/W ±10%
Color Render Index (CRI >Ra)80
Correlated Color Temperature (CCT ºK)3000K~6000K
Color Consistency (SDCM)< 5
Unified Glare Rating (UGR)<12
Light Distribution TypeI, III, VI
Beam Angle (Degrees)Diferent options regarding lens type
Upper Light Output Ratio (ULOR %)0%
Optical Compartment Tightness (IP)IP66
Auxiliary Compartment Tightness (IP)IP66
Impact Resistance (IK)IK10
Surge ProtectionBasic 4kV, Extended 10kV
Pressure & Condesation Protection
Wind Index
Explosion-Proof
PCB TypeMC-PCB
PCB MaterialAluminium
Thermal ViasYes
Led Bypass ProtectionYes
Overheating ProtectionNTC Thermistor
BrandCREE
TypeXT-E
ModelR5
Max. Luminous Efficacy (Lm/W)148 Lm/W
BrandInventronics
Series TypeEUC, EBD, Other series optional
Internal Or ExternalExternal
Isolated Or NotIsolated
IPIP67
Lifespan @ Tc=60ºc100.000 h
Surge Protection4 kV, 10kV
Overload And Short Circuit ProtectionYes
Thermal Foldback ControlOptional

Application Conditions

Tj Temperature (Tj ºC)<80ºC @ Ta=25ºC
Tc Temperature (Tc ºC)<60ºC @ Ta=25ºC
Storage Temperature (ºC)-40ºC +85ºC
Operating Temperature (ºC)-40ºC +60ºC
Operating Humidity (%RH)5-95ºRH
Dimming Function0-10V, PWM, DALI (optional)
Scheduled Dimming System6 levels steps, Optional
Constant Light Output (CLO)Optional
Other Sensors OptionsPhotoelectric, Movement, Other
Wired Communications CompatibilityYes
Wirless Communications CompatibilityYes
TypeSide and top fitting
SystemFixing 59mm diameter arm pole
Mounting Height4-12M
Fixing To Existing PoleYes
Vertical Angle AdjustmentYes
Horizontal Angle AdjustmentYes
Replaceable Light SourceYes
Replaceable DriverYes
Replaceable LensYes
Replaceable CoverYes
Housing Opening SystemStainless steel screws
Wire Connectors SystemThreaded fastener
Thermal Interface Material (TIM)Yes
Body MaterialAluminium
Fins MaterialAluminium
Extra Cooling SystemThe whole structure of radiation
Body MaterialAluminium alloy
FinishingAluminium
Color RALGrey, Black
Cover MaterialPC, Lens
Cover TypeClear
Locking SystemStainless steel screws
Light Guide Plate Material
Lens MaterialPC
Reflector Material
Diffuser Material
Cable Material3*1.0mm rubber with cold-pressed terminal
Connectors SystemsThreaded fastener
Waterproof ConnectorsYes

Product Parameters

ReferenceSystem PowerNº LEDSCurrent (mA)System Efficacy (Lm/W)Luminous Flux (Lm)Lumen Maintenance @ Ta=25ºCTj @ Ta=25ºCDimensionsWeight (Kg)
@ 3000K@ 4000K@ 5000K@ 6000K
EXSL20W12D20W12500mA105 lm/W ±10%1995210022052310L85 F10 100.000h<62ºC380*190*62mm2,8
EXSL30W12D30W700mA100 lm/W ±10%2850300031503300L80 F10 100.000h<70ºC
EXSL30W16D16500mA105 lm/W ±10%2993315033083465L85 F10 100.000h<62ºC532*220*78mm4,6
EXSL40W16D40W700mA100 lm/W ±10%3800400042004400L80 F10 100.000h<70ºC
EXSL30W24D30W24350mA110 lm/W ±10%3135330034653630L90 F10 100.000h<55ºC628*250*80mm11,6
EXSL40W24D40W500mA105 lm/W ±10%3990420044104620L85 F10 100.000h<62ºC
EXSL60W24D60W700mA100 lm/W ±10%5700600063006600L80 F10 100.000h<70ºC
EXSL40W32D40W32350mA110 lm/W ±10%4180440046204840L90 F10 100.000h<55ºC
EXSL60W32D60W500mA105 lm/W ±10%5700600063006600L85 F10 100.000h<62ºC
EXSL80W32D80W700mA100 lm/W ±10%7600800084008800L80 F10 100.000h<70ºC
EXSL60W48D60W48350mA110 lm/W ±10%6270660069307260L90 F10 100.000h<55ºC780*280*106mm14
EXSL80W48D80W500mA105 lm/W ±10%7980840088209240L85 F10 100.000h<62ºC
EXSL100W48D100W700mA100 lm/W ±10%9500100001050011000L80 F10 100.000h<70ºC
EXSL120W54D120W5411400120001260013200

Product Builder

Order Code: EXSL
Model
Power
Voltage
Control
Color CCT
Lens
Color RAL
Optionals
EXSL20W
120
100V-120V
DIM 0-10V
Dimming 0-10V
AMB
1700K 
L1
Type
(Lens 80*150)
BK
Black 
EXPEC001
Photoelectric control sensor
INTEGRATED
30W
240
200V-240V
PWM
Pulse Width Modulation
AMB2
2200K
L2
Type III
(Lens 85*135)
GR
Grey
PW·10KD05KWV
External surge protection device 10kv
INTEGRATED
40W
305
176V-305V
CLO
Constant Light Output
WW
3000K
L3
Type VI
(Lens 50*150)
PW·20K
External surge protection device  20kV
INTEGRATED
60W
UNVH
249V-528V
DALI
Digital Addresable Lighting Interface
NW
4000K
80W
UNV
90V-305V
DMX512
Control of lighting and effects of the stage
PW
5000K
100W
TRIAC
Triode for Alternating Current
CW
6000K
120W
Timer
Time Regulation System
CTLEBD
0-5V/0-10V/PWM/Timer
CTLESD-EUC
0-10V/PWM/Timer

Product dimensions

ReferenceDimensions (A*B*C)
EXSL20W12D380*190*62mm
EXSL30W12D
EXSL30W16D532*220*78mm
EXSL40W16D
EXSL30W24D628*250*80mm
EXSL40W24D
EXSL60W24D
EXSL40W32D
EXSL60W32D
EXSL80W32D
EXSL60W48D780*280*106mm
EXSL80W48D
EXSL100W48D
EXSL120W54D
ModelPcs/CtnLong (mm)Width (mm)Height (mm)Gross Weigth (kg/ctn)
12 leds1395205953.2
16 leds1532235954.9
24-32 leds168530013512
48-54 leds183533511514.5

Matters need Attention

  1. Before use, should carefully read the instructions , to avoid accidents and damage.
  2. Please wear gloves to avoid injury before installation work.
  3. Lighting installation,and wiring work must be carried out in the absence of power.
  4. Power line joints must do insulation ,waterproofing treatment.
  5. Do not look directly at the light emitting LED lighting in close distance, ensure not hurt the eyes.